how to test a furnace capacitor

How to Test a Furnace Capacitor

By Thomas Anderson
AD

Testing a furnace capacitor might seem like a daunting task, but with the right steps and tools, it can be done safely and efficiently. A capacitor is a critical component in your furnace's ignition system, storing energy to create a spark that ignites the fuel. When it fails, your furnace might not start or may exhibit poor combustion. Let's dive into a comprehensive guide on how to test a furnace capacitor, ensuring your home's comfort and safety.

Before we begin, it's crucial to turn off the power to your furnace at the circuit breaker. Safety should always be your top priority when dealing with electrical components. Once the power is off, you can proceed to test the capacitor. This guide will focus on testing a.run capacitor, which is the type commonly found in furnaces. Let's start by understanding what you'll need for the task.

Gathering Required Tools

AD
Furnace Blower Repair - loud motor and how to test a capacitor
Furnace Blower Repair - loud motor and how to test a capacitor
85K views · 8.6K reactions | Let me know Of This Was Helpful. thank You Guye For Watching amy Videos. Like & Share 🙏🏻 #hvac #heatingandcooling #airconditioning #fieldpiece | Hipolito Jr Jaramillo
85K views · 8.6K reactions | Let me know Of This Was Helpful. thank You Guye For Watching amy Videos. Like & Share 🙏🏻 #hvac #heatingandcooling #airconditioning #fieldpiece | Hipolito Jr Jaramillo
How to test capacitor
How to test capacitor

Safety Equipment

  • Work gloves
  • Safety glasses
  • Mask (for COVID protection or partisans)

Testing the Run Capacitor While the System is Running
Testing the Run Capacitor While the System is Running
How To Test The Capacitor on Your Heating/AC System
How To Test The Capacitor on Your Heating/AC System

Testing Equipment

  • Volt-ohm meter (VOM) or multimeter
  • Adjustable wrench
  • Screwdriver
  • Wire strippers
  • Electrical tape

Locating the Furnace Capacitor

Furnace capacitors are usually found near the blower motor, attached to the control box, or close to the igniter. They are cylindrical with wires running to and from them. The capacitor will have two terminals, marked '+' and '-'.

AD

Identifying the right component is crucial. Furnace capacitors can range in size and capacity, with common ratings being around 2-10 microfarads (µF) and 100-200 volts (V). If you're unsure, consult your furnace's manual or look up your model online.

Capacitor Discharge

Safety warning: Always discharge a capacitor before touching or testing it to prevent electric shock.

Discharging a capacitor is simple and crucial. Use your volt-ohm meter (VOM) set to 'ohms' to discharge the capacitor, ensuring the safety of yourself and your equipment. Touch one probe to each terminal. You should see the needle move, indicating the discharge. Once the needle returns to zero, the capacitor is safe to handle.

AD

Inspecting the Capacitor

Testing the Furnace Capacitor

Now that your capacitor is discharged and inspected, it's time to test its capacitance and resistance. For this, you'll need a multimeter set to the 'capacitance' or 'µF' setting.

Touch one probe to each terminal, and read the capacitance value. It should fall within the rated value for your capacitor, usually printed on its casing. If the capacitance is significantly lower or higher than the rated value, the capacitor is probably faulty and should be replaced.

AD

Resistance Test

Next, set your multimeter to the 'resistance' or 'ohms' setting. Touch one probe to each terminal and take the reading. A good capacitor should have infinite resistance, or a very high value (close to infinity on your multimeter). If the resistance is low, the capacitor is likely leaking current and needs replacing.

Polarity Check

Finally, verify the capacitor's polarity. Touch one probe to each terminal while checking the multimeter display. It should show a positive value if the capacitor is connected correctly, or a negative value if it's reversed. The '+' and '-' marks on the capacitor casing should correspond to the positive and negative leads on your multimeter.

Replacing the Furnace Capacitor

If your capacitor tests faulty, it's time for a replacement. Disconnect the wires from the old capacitor, being careful not to let the leads touch. Install the new capacitor, ensuring the polarity (+/-) matches the wiring. Tighten the connections securely and reinsulate as needed.

Remember to replace the cover panel and turn the power back on at the circuit breaker. Test your furnace to ensure it's working properly before calling it a day.

Frequent capacitor testing and replacement are essential for maintaining your furnace's efficiency and longevity. While this guide provides a solid foundation, always consult your furnace's manual for model-specific instructions. If you're unsure about any step, don't hesitate to call a professional technicians. Your safety and the proper functioning of your furnace are crucial.

Regular maintenance and testing of your furnace's components, including the capacitor, ensure your home stays comfortable and safe throughout the year. So, don't wait - make capacitor testing a part of your regular home maintenance routine today!

AD