how to replace furnace flame sensor

How to Replace a Furnace Flame Sensor: Step-by-Step Guide

By Kevin Young
AD

Nothing's worse than waking up to a cold home on a chilly morning, especially when it's due to a faulty furnace flame sensor. The flame sensor is a crucial safety component that ensures your furnace doesn't produce dangerous carbon monoxide when there's no ignition. Replacing it when it malfunctions can seem daunting, but with the right steps, you can restore your furnace's functionality and safety in no time. Let's guide you through the process.

Before we dive in, remember that safety is paramount when dealing with furnaces. Always ensure the gas supply to your furnace is shut off at the main valve, and the furnace itself is turned off at the power switch. Also, consider these helpful tips to make the process smoother:

Understanding Your Furnace

First, familiarize yourself with your furnace type and model. This will help you locate the flame sensor and understand its specific mechanisms. Most furnaces use either an induced draft blower or a constant-pressure blower to circulate air. Knowing this can aid in the replacement process.

AD
How to Replace Flame Sensor on Furnace
How to Replace Flame Sensor on Furnace
How to replace the furnace flame sensor
How to replace the furnace flame sensor
How to Check Flame Sensor on Furnace | 7 Easy Steps (2026)
How to Check Flame Sensor on Furnace | 7 Easy Steps (2026)

Next, identify the flame sensor. On traditional furnaces, it's usually a thin rod that fits into the flame rollout tube and is accessible from the front. On electronic ignition systems, it might be a ceramic or metal probe near the burner.

Preparation for Replacement

Before you begin, gather your tools. You'll need a Philips screwdriver, a slot screwdriver, adjustable wrenches, possibly a drill (if your model requires it), and pliers. You'll also need a new flame sensor, ensuring it's compatible with your furnace model.

How to Tell if Flame Sensor Is Bad
How to Tell if Flame Sensor Is Bad
My Furnace Turns on Then off After a Few Minutes: Find out Why
My Furnace Turns on Then off After a Few Minutes: Find out Why

Now, let's look at the specific steps for replacement, divided into two common furnace types:

Post-Pilot Furnace Sensors

  1. Remove the panel enclosing the burner assembly and flame sensor.
  2. Remove the sensors' mounting hardware. Usually, this involves unscrewing or unbolting the sensor.
  3. Remove the old sensor, taking note of its position and orientation.
  4. Clean the area around the flame sensor to remove any soot buildup.
  5. Insert and secure the new sensor in the same position and orientation as the old one.
  6. Reinstall the panel and ensure it's securely fastened.

IPI (Intermittent Pilot Ignition) Furnace Sensors

  1. Locate the flame sensor. It's usually attached to the burner igniter assembly.
  2. Remove the mounting screws and extract the sensor from its slot.
  3. Inspect the new sensor. If it's a ceramic type, ensure the glow pin (metal wire) isn't bent. If it's a metal rod type, it should have a 45-degree bend at the end.
  4. Insert the new sensor into the slot, ensuring the sensing tip is within the flame path.
  5. Reassemble and test your furnace.

After replacing the flame sensor, wait for about 30 minutes to an hour before turning on your furnace to allow any residual gas to dissipate. Then, test the furnace to ensure it's working correctly.

AD

Remember, if you're unsure about any part of the process, always call a professional. DIY repairs can void warranties and cause safety issues if done incorrectly. Lastly, scheduling regular professional maintenance can prevent issues like flame sensor malfunction in the first place.

AD